| Customization: | Available |
|---|---|
| Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
| Output Type: | Triple |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency



Function | Specification | |
Power input | Input Voltage(V) | AC 3PH 380V(-15%)~440V(+10%) Rated Voltage:380V |
Input Current(A) | Please refer to" Product rated current parameters" | |
Input Frequency(Hz) | 50Hz or 60Hz, Allowance range:47~63Hz | |
Power output | Output Voltage(V) | 0~ Input Voltage |
Output Current(A) | Please refer to" Product rated current parameters" | |
Output Power(kW) | Please refer to" Product rated current parameters" | |
Output Frequency(Hz) | 0-400Hz | |
Technical control performance | Control Mode | Space voltage vector control mode, no PG vector control mode |
Moto r Type | Asynchronous motor, synchronous motor. | |
Speed regulation ratio | Asynchronous motor 1:200(SVC), synchronous motor 1:50 (SVC), 1:1000(VC) | |
Speed control accuracy | ±0.2%( no PG vector control mode) | |
Speed fluctuation | ±0.3%(no PG vector control mode) | |
Torque response | <20ms(no PG vector control mode) | |
Torque control accuracy | 10%(no PG vector control mode) | |
Starting Torque | Asynchronous motor:0.25Hz/150%(no PG vector control mode) Synchronous motor:1Hz/150%(no PG vector control mode) | |
Overload Capacity | (G type machine):150% rated current 1min, 180% rated current 10S,200% rated current 1s(P type machine): 120% rated current 1min,150% rated current 3S,160% rated current 1s | |
Operational control performance | Frequency setting mode | Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLCsetting, PID setting, Modbus communication setting, PROFIBUS communication setting. Switch between the combination and single setting channel. |
Automatic voltage adjustment function | Keep constant voltage automatically when the grid voltage transients | |
Failsafe function | Failsafe Function:4 common inputs, the Max. frequency: 1kHz, internal impedance:3.3kΩ;2 high speed input, the Max. frequency: 100kHz | |
Speed tracking restart function | Speed tracking restart function: The inverter(VFD) can track the rotating speed of the rotating motor in full frequency band and Smooth starting of the rotating motor | |
Peripheral interface | Analog input | 1(Al1)0~10V/0~20mA,1(Al2)-10~10V |
Analog output | 2(AO1,AO2)0~10V /0~20mA | |
Terminal analog input resolution | ≤20mV | |
Terminal switch input resolution | ≤2ms | |
Digital input | 4 common inputs, the Max. frequency: 1kHz, internal impedance: 3.3kΩ; 2 high speed input, the Max. frequency: 100kHz | |
Digital output | 1 DO terminal output collector open-circuit output | |
Relay output | 2 programmable relay outputsT1A NO, T1B NC, T1C common terminalT2A NO, T2BNC,T2C common terminalContactor capability: 3A/AC250V,1A/DC30V | |
Communication interface | 1 RS485(non-isolated) | |
Extended interfaces | Support 1-channel expansion card slot, which can install I/O card, communication card, etc | |